This describes the Z-Wave device DSC17, manufactured by AEON Labs with the thing type UID of aeon_dsc17_00_000.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The DSC17 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
The Aeon Labs Micro Double SES is a power binary switch device based on Z-wave routing slave library V5.02 Patch3
Toggle external button or push internal button.
Toggle external button 10 times in quick succession to initiate removing from the Z-Wave network or push internal button.
The following table summarises the channels available for the DSC17 -:
| Channel Name | Channel ID | Channel Type | Category | Item Type |
|---|---|---|---|---|
| Switch | switch_binary | switch_binary | Switch | Switch |
| Sensor (power) | sensor_power | sensor_power | Energy | Number |
| Electric meter (watts) | meter_watts | meter_watts | Energy | Number |
| Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number |
| Reset Meter | meter_reset | meter_reset | Energy | Switch |
| Switch 1 | switch_binary1 | switch_binary | Switch | Switch |
| Switch 2 | switch_binary2 | switch_binary | Switch | Switch |
Switch the power on and off.
The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.
Indicates the energy consumption (kWh).
The sensor_power channel is of type sensor_power and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power consumption.
The meter_watts channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.
Reset the meter.
The meter_reset channel is of type meter_reset and supports the Switch item and is in the Energy category.
Switch the power on and off.
The switch_binary1 channel is of type switch_binary and supports the Switch item and is in the Switch category.
Switch the power on and off.
The switch_binary2 channel is of type switch_binary and supports the Switch item and is in the Switch category.
The following table provides a summary of the 16 configuration parameters available in the DSC17. Detailed information on each parameter can be found in the sections below.
| Param | Name | Description |
|---|---|---|
| 2 | Blink | This is a double byte value. |
| 3 | Current Overload Protection | Load current>=10.A,2 minutes later ,automatic turn off the load |
| 80 | Notification on Status Change | Enables automatic notifications to associated devices |
| 90 | Enables/disables parameter 91 and 92 | Automated sending of a Report triggered by minimal change of value. |
| 91 | Minimum Change to send Report (Watt) | The value represents the minimum change in Watts for a Report to be sent |
| 92 | Minimum Change to send Report (%) | The value represents the min. change in Watts Percent for a report to be sent |
| 100 | Set 101-103 to default. | |
| 101 | Automatic reports for group 1 | Which reports need to send automatically in timing intervals for group 1 |
| 102 | Automatic reports for group 2 | Which reports need to send automatically in timing intervals for group 2 |
| 103 | Automatic reports for group 3 | Which reports need to send automatically in timing intervals for group 3 |
| 110 | Set 111-113 to default. | |
| 111 | Interval to send out reports of group 1 | |
| 112 | Interval to send out reports of group 2 | |
| 113 | Interval to send out reports of group 3 | |
| 120 | Set External Switch/Button Control mode | |
| 255 | Reset to the default Configuration. | |
| Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
This is a double byte value. This is a double byte value. The LSB defines the total time the device need to blink. The value is set in seconds. The MSB defines the on/off interval of the blinking. The unit is 0.1 s.
Configuration Value 1 is to Specify the time that Micro Double SES need blink, The unit is Second; Configuration Value 2 is to Specify the Cycle of on/off, the unit of it is 0.1 second. For example: if we set Configuration Value 1 to '15',Configuration Value 2 to '10',then Micro Double SES will open 0.5 second, close 0.5 second, and repeat for 14 times. Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0.
This parameter has the configuration ID config_2_2 and is of type INTEGER.
Load current>=10.A,2 minutes later ,automatic turn off the load
The following option values may be configured -:
| Value | Description |
|---|---|
| 0 | Disabled |
| 1 | Enabled |
The manufacturer defined default value is 0 (Disabled).
This parameter has the configuration ID config_3_1 and is of type INTEGER.
Enables automatic notifications to associated devices Parameter to Enable to send notification to associated devices (Group 1) when the state of Micro Smart Switch's load changed The following option values may be configured -:
| Value | Description |
|---|---|
| 0 | nothing |
| 1 | Hail CC Sent |
| 2 | Basic CC Report Sent |
The manufacturer defined default value is 0 (nothing).
This parameter has the configuration ID config_80_1 and is of type INTEGER.
Automated sending of a Report triggered by minimal change of value. Parameter to Enable/Disable automated sending of a Report triggered by minimal change of value. The following option values may be configured -:
| Value | Description |
|---|---|
| 0 | Deavtivate |
| 1 | Activate |
The manufacturer defined default value is 0 (Deavtivate).
This parameter has the configuration ID config_90_1 and is of type INTEGER.
The value represents the minimum change in Watts for a Report to be sent
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 50.
This parameter has the configuration ID config_91_2 and is of type INTEGER.
The value represents the min. change in Watts Percent for a report to be sent
Values in the range 0 to 100 may be set.
The manufacturer defined default value is 10.
This parameter has the configuration ID config_92_1 and is of type INTEGER.
The following option values may be configured -:
| Value | Description |
|---|---|
| 0 | Disabled |
| 1 | Enabled |
The manufacturer defined default value is 0 (Disabled).
This parameter has the configuration ID config_100_1_wo and is of type INTEGER.
This is a write only parameter.
Which reports need to send automatically in timing intervals for group 1 The value is a combination number made up of the sum of the values for the individual parameters. The parameters have the values: KWH=8, Wattage=4, Current=2, Voltage=1. The following option values may be configured, in addition to values in the range 0 to 15 -:
| Value | Description |
|---|---|
| 0 | Disabled |
| 1 | Voltage |
| 2 | Current |
| 4 | Wattage |
| 8 | kWh |
| 15 | All Values |
The manufacturer defined default value is 0 (Disabled).
This parameter has the configuration ID config_101_4 and is of type INTEGER.
Which reports need to send automatically in timing intervals for group 2 The value is a combination number made up of the sum of the values for the individual parameters. The parameters have the values: KWH=8, Wattage=4, Current=2, Voltage=1. The following option values may be configured, in addition to values in the range 0 to 15 -:
| Value | Description |
|---|---|
| 0 | Disabled |
| 1 | Voltage |
| 2 | Current |
| 4 | Wattage |
| 8 | kWh |
| 15 | All Values |
The manufacturer defined default value is 0 (Disabled).
This parameter has the configuration ID config_102_4 and is of type INTEGER.
Which reports need to send automatically in timing intervals for group 3 The value is a combination number made up of the sum of the values for the individual parameters. The parameters have the values: KWH=8, Wattage=4, Current=2, Voltage=1. The following option values may be configured, in addition to values in the range 0 to 15 -:
| Value | Description |
|---|---|
| 0 | Disabled |
| 1 | Voltage |
| 2 | Current |
| 4 | Wattage |
| 8 | kWh |
| 15 | All Values |
The manufacturer defined default value is 0 (Disabled).
This parameter has the configuration ID config_103_4 and is of type INTEGER.
The following option values may be configured -:
| Value | Description |
|---|---|
| 0 | Disabled |
| 1 | Enabled |
The manufacturer defined default value is 0 (Disabled).
This parameter has the configuration ID config_110_1_wo and is of type INTEGER.
This is a write only parameter.
Values in the range 1 to 2678400 may be set.
The manufacturer defined default value is 600.
This parameter has the configuration ID config_111_4 and is of type INTEGER.
Values in the range 1 to 2678400 may be set.
The manufacturer defined default value is 600.
This parameter has the configuration ID config_112_4 and is of type INTEGER.
Values in the range 1 to 2678400 may be set.
The manufacturer defined default value is 600.
This parameter has the configuration ID config_113_4 and is of type INTEGER.
The following option values may be configured -:
| Value | Description |
|---|---|
| 0 | Momentary button mode |
| 1 | 2-state switch mode |
| 255 | Unidentified mode |
The manufacturer defined default value is 255 (Unidentified mode).
This parameter has the configuration ID config_120_1 and is of type INTEGER.
The following option values may be configured -:
| Value | Description |
|---|---|
| 0 | Disabled |
| 1 | Enabled |
The manufacturer defined default value is 0 (Disabled).
This parameter has the configuration ID config_255_1 and is of type INTEGER.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
| Value | Description |
|---|---|
| 0 | Exclude from All On and All Off groups |
| 1 | Include in All On group |
| 2 | Include in All Off group |
| 255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode and is of type INTEGER.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The DSC17 supports 3 association groups.
Association group 1 supports 5 nodes.
Association group 2 supports 5 nodes.
Association group 3 supports 5 nodes.
| Command Class | Comment |
|---|---|
| COMMAND_CLASS_NO_OPERATION_V1 | |
| COMMAND_CLASS_BASIC_V1 | |
| COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
| COMMAND_CLASS_SWITCH_ALL_V1 | |
| COMMAND_CLASS_SENSOR_MULTILEVEL_V3 | |
| COMMAND_CLASS_METER_V2 | |
| COMMAND_CLASS_MULTI_CHANNEL_V2 | |
| COMMAND_CLASS_CONFIGURATION_V1 | |
| COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
| COMMAND_CLASS_ASSOCIATION_V1 | |
| COMMAND_CLASS_VERSION_V1 |
| Command Class | Comment |
|---|---|
| COMMAND_CLASS_BASIC_V1 | |
| COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
| Command Class | Comment |
|---|---|
| COMMAND_CLASS_BASIC_V1 | |
| COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.