This describes the Z-Wave device MT02646, manufactured by Devolo with the thing type UID of devolo_mt02646_00_000.
The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.
The MT02646 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
The Home Control Smart Metering Plug can be plugged into any wall outlet in the home. It enhances every
connected device with useful functions, such as time-controlled enabling and disabling or power monitoring
Push the front button three times rapidly within 2 seconds.
Push the front button three times rapidly within 2 seconds.
The following table summarises the channels available for the MT02646 -:
| Channel Name | Channel ID | Channel Type | Category | Item Type |
|---|---|---|---|---|
| Switch | switch_binary | switch_binary | Switch | Switch |
| Electric meter (watts) | meter_watts | meter_watts | Energy | Number |
| Electric meter (power factor) | meter_powerfactor | meter_powerfactor | Energy | Number |
| Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number |
| Electric meter (amps) | meter_current | meter_current | Energy | Number |
| Electric meter (volts) | meter_voltage | meter_voltage | Energy | Number |
| Reset the total power consumption | meter_reset | meter_reset | Energy | Switch |
| Alarm | alarm_general | alarm_general | Alarm | Switch |
Switch the power on and off.
The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.
Indicates the instantaneous power consumption.
The meter_watts channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power factor.
The meter_powerfactor channel is of type meter_powerfactor and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous current consumption.
The meter_current channel is of type meter_current and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous voltage.
The meter_voltage channel is of type meter_voltage and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.
Reset the meter.
The meter_reset channel is of type meter_reset and supports the Switch item and is in the Energy category.
Indicates if an alarm is triggered.
The alarm_general channel is of type alarm_general and supports the Switch item and is in the Alarm category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch item type -:
| Value | Label |
|---|---|
| OFF | OK |
| ON | Alarm |
The following table provides a summary of the 9 configuration parameters available in the MT02646. Detailed information on each parameter can be found in the sections below.
| Param | Name | Description |
|---|---|---|
| 1 | Watt Meter Report Period | multiples of 5s |
| 2 | KWH Meter Report Period | number of 10 minute intervals |
| 3 | Threshold of current for Load Caution | 1300*0.01A = 13A |
| 4 | Threshold of KWh for Load Caution | load caution threshold |
| 5 | Restore switch state mode | Restore switch state mode. |
| 6 | Mode of switch off function | Mode of switch off function. |
| 7 | LED indication mode | Restore switch state mode. |
| 8 | Auto off timer | Auto off timer. 0 will disable the auto off function. |
| 9 | RF off command mode | RF off command mode |
| Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
multiples of 5s Enable automatic interval in seconds reporting with an interval of 5s * the value. Set to 0 will disable the autoreporting function. The following option values may be configured -:
| Value | Description |
|---|---|
| 0 | Disable |
The manufacturer defined default value is 720.
This parameter has the configuration ID config_1_2 and is of type INTEGER.
number of 10 minute intervals Enable automatic interval in minutes reporting with an interval of 10min * the value. Set to 0 will disable the autoreporting function. The following option values may be configured -:
| Value | Description |
|---|---|
| 0 | Disable |
The manufacturer defined default value is 6.
This parameter has the configuration ID config_2_2 and is of type INTEGER.
1300*0.01A = 13A
Values in the range 10 to 1300 may be set.
The manufacturer defined default value is 1300.
This parameter has the configuration ID config_3_2 and is of type INTEGER.
load caution threshold Enable automatic warning when the accumulated kWh power consumption exceeds the setting value from 1KWh ~ 10000KWh.. Set to 0 will disable kWh load caution reporting. Values in the range 1 to 10000 may be set.
The manufacturer defined default value is 10000.
This parameter has the configuration ID config_4_2 and is of type INTEGER.
Restore switch state mode.
The following option values may be configured -:
| Value | Description |
|---|---|
| 0 | Switch OFF after power on |
| 1 | resume previous state |
| 2 | Switch ON after power on |
The manufacturer defined default value is 1 (resume previous state).
This parameter has the configuration ID config_5_1 and is of type INTEGER.
Mode of switch off function.
The following option values may be configured -:
| Value | Description |
|---|---|
| 0 | SWITCH OFF commands received are ignored. |
| 1 | SWITCH OFF commands received are honored. |
The manufacturer defined default value is 1 (SWITCH OFF commands received are honored.).
This parameter has the configuration ID config_6_1 and is of type INTEGER.
Restore switch state mode.
The following option values may be configured -:
| Value | Description |
|---|---|
| 1 | The LED follows the state of the switch. |
| 2 | LED off with load ON |
| 3 | Flash mode |
The manufacturer defined default value is 1 (The LED follows the state of the switch.).
This parameter has the configuration ID config_7_1 and is of type INTEGER.
Auto off timer. 0 will disable the auto off function.
The following option values may be configured -:
| Value | Description |
|---|---|
| 0 | Disable |
The manufacturer defined default value is 0 (Disable).
This parameter has the configuration ID config_8_2 and is of type INTEGER.
RF off command mode
The following option values may be configured -:
| Value | Description |
|---|---|
| 0 | SWITCH ALL OFF turns Switch OFF |
| 1 | Ignore ALL OFF |
| 2 | If ALL OFF is received, turn ON if it is OFF |
| 3 | SWITCH ALL OFF turns Switch ON |
The manufacturer defined default value is 0 (SWITCH ALL OFF turns Switch OFF).
This parameter has the configuration ID config_9_1 and is of type INTEGER.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
| Value | Description |
|---|---|
| 0 | Exclude from All On and All Off groups |
| 1 | Include in All On group |
| 2 | Include in All Off group |
| 255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode and is of type INTEGER.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The MT02646 supports 1 association group.
Grouping 1 includes, SWITCH_BINARY_REPORT, METER_REPORT, ALARM_REPORT.
Association group 1 supports 1 node.
| Command Class | Comment |
|---|---|
| COMMAND_CLASS_NO_OPERATION_V1 | |
| COMMAND_CLASS_BASIC_V1 | |
| COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
| COMMAND_CLASS_SWITCH_ALL_V1 | |
| COMMAND_CLASS_METER_V3 | |
| COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
| COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
| COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | |
| COMMAND_CLASS_CONFIGURATION_V1 | |
| COMMAND_CLASS_ALARM_V1 | |
| COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 | |
| COMMAND_CLASS_POWERLEVEL_V1 | |
| COMMAND_CLASS_PROTECTION_V2 | |
| COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 | |
| COMMAND_CLASS_ASSOCIATION_V2 | |
| COMMAND_CLASS_VERSION_V2 | |
| COMMAND_CLASS_SECURITY_V1 |