| layout | documentation |
|---|---|
| title | 005206 - ZWave |
{% include base.html %}
This describes the Z-Wave device 005206, manufactured by Popp & Co with the thing type UID of popp_005206_00_000.
The device is in the category of Sensor, defining Device used to measure something.
The 005206 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The 005206 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the Wakeup Information section below for further information.
Z-Weather is a cup anemometer for Z-Wave installations. It continually measures the wind speed and can, for example, trigger closing of the awning and blinds if it is too windy. It also measures the amount of rotation, enabling calculation of the wind yield per day or per year. In addition, Z-Weather includes sensors for humidity, temperature, pressure and dew point, essentially providing the core sensors of a weather station.
Push the button 3 times within 1.5 seconds
Push the button 3 times within 1.5 seconds
The 005206 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.
The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
Push the button once within 1.5 seconds
The following table summarises the channels available for the 005206 -:
| Channel Name | Channel ID | Channel Type | Category | Item Type |
|---|---|---|---|---|
| Binary Sensor | sensor_binary | sensor_binary | Switch | |
| Sensor (temperature) | sensor_temperature | sensor_temperature | Temperature | Number:Temperature |
| Sensor (relative humidity) | sensor_relhumidity | sensor_relhumidity | Humidity | Number |
| Sensor (barometric pressure) | sensor_barpressure | sensor_barpressure | Pressure | Number |
| Sensor (velocity) | sensor_velocity | sensor_velocity | Number | |
| Sensor (dew point) | sensor_dewpoint | sensor_dewpoint | Temperature | Number |
| Sensor (luminance) | sensor_luminance | sensor_luminance | Number | |
| Electric meter (pulses) | meter_pulse | meter_pulse | Energy | Number |
| Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number |
| Battery Level | battery-level | system.battery_level | Battery | Number |
Indicates if a sensor has triggered.
The sensor_binary channel is of type sensor_binary and supports the Switch item. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch item type -:
| Value | Label |
|---|---|
| ON | Triggered |
| OFF | Untriggered |
Indicates the current temperature.
The sensor_temperature channel is of type sensor_temperature and supports the Number:Temperature item and is in the Temperature category.
Indicates the current relative humidity.
The sensor_relhumidity channel is of type sensor_relhumidity and supports the Number item and is in the Humidity category. This is a read only channel so will only be updated following state changes from the device.
Indicates the barometric pressure.
The sensor_barpressure channel is of type sensor_barpressure and supports the Number item and is in the Pressure category. This is a read only channel so will only be updated following state changes from the device.
Indicates the current velocity.
The sensor_velocity channel is of type sensor_velocity and supports the Number item. This is a read only channel so will only be updated following state changes from the device.
Indicates the dewpoint.
The sensor_dewpoint channel is of type sensor_dewpoint and supports the Number item and is in the Temperature category. This is a read only channel so will only be updated following state changes from the device.
Indicates the current light reading.
The sensor_luminance channel is of type sensor_luminance and supports the Number item. This is a read only channel so will only be updated following state changes from the device.
Indicates the pulse count.
The meter_pulse channel is of type meter_pulse and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The system.battery-level channel is of type system.battery-level and supports the Number item and is in the Battery category.
This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.
The following table provides a summary of the 2 configuration parameters available in the 005206. Detailed information on each parameter can be found in the sections below.
| Param | Name | Description |
|---|---|---|
| 1 | Wind Speed Action Threshold | Available Parameters: 0 - Off; 1 - 30: threshold in m/s - Default = 6 m/s |
| 2 | Twilight Action Threshold | Set from 0 - 100 % Default = 37% (street lighting) |
| Wakeup Interval | Sets the interval at which the device will accept commands from the controller | |
| Wakeup Node | Sets the node ID of the device to receive the wakeup notifications |
Available Parameters: 0 - Off; 1 - 30: threshold in m/s - Default = 6 m/s
Values in the range 0 to 30 may be set.
The manufacturer defined default value is 6.
This parameter has the configuration ID config_1_1 and is of type INTEGER.
Set from 0 - 100 % Default = 37% (street lighting)
Values in the range 0 to 100 may be set.
The manufacturer defined default value is 37.
This parameter has the configuration ID config_2_1 and is of type INTEGER.
The wakeup interval sets the period at which the device will listen for messages from the controller. This is required for battery devices that sleep most of the time in order to conserve battery life. The device will wake up at this interval and send a message to the controller to tell it that it can accept messages - after a few seconds, it will go back to sleep if there is no further communications.
This setting is defined in seconds. It is advisable not to set this interval too short or it could impact battery life. A period of 1 hour (3600 seconds) is suitable in most instances.
Note that this setting does not affect the devices ability to send sensor data, or notification events.
This parameter has the configuration ID wakeup_interval and is of type INTEGER.
When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address. In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.
This parameter has the configuration ID wakeup_node and is of type INTEGER.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The 005206 supports 4 association groups.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.
Association group 1 supports 5 nodes.
Association group 2 supports 5 nodes.
Association group 3 supports 5 nodes.
Association group 4 supports 5 nodes.
| Command Class | Comment |
|---|---|
| COMMAND_CLASS_NO_OPERATION_V1 | |
| COMMAND_CLASS_BASIC_V1 | |
| COMMAND_CLASS_SENSOR_BINARY_V1 | |
| COMMAND_CLASS_SENSOR_MULTILEVEL_V6 | |
| COMMAND_CLASS_METER_V3 | |
| COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
| COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
| COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
| COMMAND_CLASS_CONFIGURATION_V1 | |
| COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
| COMMAND_CLASS_POWERLEVEL_V1 | |
| COMMAND_CLASS_BATTERY_V1 | |
| COMMAND_CLASS_WAKE_UP_V2 | |
| COMMAND_CLASS_ASSOCIATION_V2 | |
| COMMAND_CLASS_VERSION_V2 | |
| COMMAND_CLASS_LANGUAGE_V1 | |
| COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2 | |
| COMMAND_CLASS_MULTI_CMD_V1 | |
| COMMAND_CLASS_ASSOCIATION_COMMAND_CONFIGURATION_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.