This describes the Z-Wave device ZMNHDA, manufactured by Goap with the thing type UID of qubino_zmnhda_00_000.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The ZMNHDA supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
This Z-Wave module is used for dimming the bulb or to manage the speed of a fan. The module can be controlled either through a Z-Wave network or through the wall switch.
The module is designed to be mounted inside a “flush mounting box” and is hidden behind a traditional wall switch.
Module measures power consumption of bulb or fan and supports connection of digital temperature sensor.
- Connect module to power supply,
- bring module within maximum 1 meter (3 feet) of the main controller,
- enable add/remove mode on main controller,
- auto-inclusion (30 minutes after connected to power supply) or
- press service button S for more than 2 seconds or
- press push button I1 three times within 3s (3 times change switch state within 3 seconds).
- Connect module to power supply,
- bring module within maximum 1 meter (3 feet) of the main controller,
- enable add/remove mode on main controller,
- press service button S for more than 6 seconds or
- press push button I1 five times within 3s (5 times change switch state within 3 seconds)
By this function all parameters of the module are set to default values and own ID is deleted.
If service button S is pressed more than 2 and less than 6 second module is excluded, but configuration parameters are not set to default values.
The following table summarises the channels available for the ZMNHDA -:
| Channel Name | Channel ID | Channel Type | Category | Item Type |
|---|---|---|---|---|
| Switch [Deprecated] | switch_binary | switch_binary | Switch | Switch |
| Dimmer | switch_dimmer | switch_dimmer | DimmableLight | Dimmer |
| Sensor (temperature) | sensor_temperature | sensor_temperature | Temperature | Number:Temperature |
| Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number |
| Electric meter (watts) | meter_watts | meter_watts | Energy | Number |
| Meter reset | meter_reset | meter_reset | Energy | Switch |
| Binary Sensor 1 | sensor_binary1 | sensor_binary | Switch | |
| Binary Sensor 2 | sensor_binary2 | sensor_binary | Switch |
Switch the power on and off.
The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.
Note: This channel is marked as deprecated so should not be used.
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer channel is of type switch_dimmer and supports the Dimmer item and is in the DimmableLight category.
Indicates the current temperature.
The sensor_temperature channel is of type sensor_temperature and supports the Number:Temperature item and is in the Temperature category.
Indicates the energy consumption (kWh).
The meter_kwh channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power consumption.
The meter_watts channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.
Reset the meter.
The meter_reset channel is of type meter_reset and supports the Switch item and is in the Energy category.
Indicates if a sensor has triggered.
The sensor_binary1 channel is of type sensor_binary and supports the Switch item. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch item type -:
| Value | Label |
|---|---|
| ON | Triggered |
| OFF | Untriggered |
Indicates if a sensor has triggered.
The sensor_binary2 channel is of type sensor_binary and supports the Switch item. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch item type -:
| Value | Label |
|---|---|
| ON | Triggered |
| OFF | Untriggered |
The following table provides a summary of the 11 configuration parameters available in the ZMNHDA. Detailed information on each parameter can be found in the sections below.
| Param | Name | Description |
|---|---|---|
| 1 | Input 1 switch type | Switch type (input I1) |
| 2 | Input 2 contact type | Input 2 contact type |
| 3 | Input 3 contact type | Input 3 contact type |
| 10 | Activate / deactivate functions ALL ON/ALL OFF | Activate / deactivate functions ALL ON/ALL OFF |
| 30 | State of the device after a power failure | State of the device after a power failure |
| 40 | Power reporting in Watts on power change | Set value means percentage |
| 42 | Power reporting in Watts by time interval | Power reporting in Watts by time interval |
| 60 | Minimum dimming value | Minimum dimming value |
| 61 | Maximum dimming value | Maximum dimming value |
| 65 | Dimming time (soft on/off) | Dimming time (soft on/off) |
| 66 | Dimming time when key pressed | Dimming time when key pressed |
| Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Switch type (input I1)
The following option values may be configured -:
| Value | Description |
|---|---|
| 0 | mono-stable switch (push button) |
| 1 | bi-stable (toggle) switch |
The manufacturer defined default value is 0 (mono-stable switch (push button)).
This parameter has the configuration ID config_1_1 and is of type INTEGER.
Input 2 contact type
The following option values may be configured -:
| Value | Description |
|---|---|
| 0 | NO (normally open) input type |
| 1 | NC (normally close) input type |
The manufacturer defined default value is 0 (NO (normally open) input type).
This parameter has the configuration ID config_2_1 and is of type INTEGER.
Input 3 contact type
The following option values may be configured -:
| Value | Description |
|---|---|
| 0 | NO (normally open) input type |
| 1 | NC (normally close) input type |
The manufacturer defined default value is 0 (NO (normally open) input type).
This parameter has the configuration ID config_3_1 and is of type INTEGER.
Activate / deactivate functions ALL ON/ALL OFF Flush 1 relay module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system. The following option values may be configured -:
| Value | Description |
|---|---|
| 0 | ALL ON is not active ALL OFF is not active |
| 1 | ALL ON is not active ALL OFF active |
| 2 | ALL ON active ALL OFF is not active |
| 255 | ALL ON active, ALL OFF active |
The manufacturer defined default value is 255 (ALL ON active, ALL OFF active).
This parameter has the configuration ID config_10_1 and is of type INTEGER.
State of the device after a power failure
The following option values may be configured -:
| Value | Description |
|---|---|
| 0 | Saves its state before power failure |
| 1 | Off |
The manufacturer defined default value is 0 (Saves its state before power failure).
This parameter has the configuration ID config_30_1 and is of type INTEGER.
Set value means percentage
- 0 – Reporting Disabled
- 1 – 100 = 1% - 100% Reporting enabled.
Power report is send (push) only when actual power in Watts in real time change for more than set percentage comparing to previous actual power in Watts, step is 1%. Values in the range 0 to 100 may be set.
The manufacturer defined default value is 5.
This parameter has the configuration ID config_40_1 and is of type INTEGER.
Power reporting in Watts by time interval Set value means time interval (0 – 65535) in seconds, when power report is send.
- default value 300 (power report in Watts is send each 300s)
- 0 – Reporting Disabled
- 1 – 65535 = 1 second – 65535 seconds. Reporting enabled.
Power report is send with time interval set by entered value. Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 300.
This parameter has the configuration ID config_42_2 and is of type INTEGER.
Minimum dimming value
- Default value 1 (Minimum dimming value is 1%)
- 1- 98 = 1% – 98%, step is 1%. Minimum dimming values is set by entered value.
NOTE: The maximum level may not be lower than the minimum level! 1% min. dimming value is defined by Z-Wave multilevel device class Values in the range 0 to 98 may be set.
The manufacturer defined default value is 1.
This parameter has the configuration ID config_60_1 and is of type INTEGER.
Maximum dimming value
- Default value 99 (Maximum dimming value is 99 %)
- 2- 99 = 2% – 99%, step is 1%. Maximum dimming values is set by entered value.
NOTE: The maximum level may not be lower than the minimum level! 99% max. dimming value is defined by Z-Wave multilevel device class Values in the range 2 to 99 may be set.
The manufacturer defined default value is 99.
This parameter has the configuration ID config_61_1 and is of type INTEGER.
Dimming time (soft on/off) Set value means time of moving the Dimmer between min. and max. dimming values by short press of push button I1 or controlled through UI.
- Default value 100 (Dimming time between min. and max. dimming values is 1s)
- 1- 255 = 10mseconds – 2550mseconds (2,55s), step is 10mseconds Values in the range 1 to 255 may be set.
The manufacturer defined default value is 100.
This parameter has the configuration ID config_65_1 and is of type INTEGER.
Dimming time when key pressed Time of moving the Dimmer between min. and max dimming values by continues hold of push button I1.
Default value 3 (Dimming time between min. and max. dimming values is 3s)
1- 255 = 1 second – 255 seconds Values in the range 1 to 255 may be set.
The manufacturer defined default value is 3.
This parameter has the configuration ID config_66_1 and is of type INTEGER.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
| Value | Description |
|---|---|
| 0 | Exclude from All On and All Off groups |
| 1 | Include in All On group |
| 2 | Include in All Off group |
| 255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode and is of type INTEGER.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZMNHDA supports 4 association groups.
(triggered at changes of state/value of the Flush dimmer)
Association group 1 supports 4 nodes.
Association group 2 supports 4 nodes.
Association group 3 supports 4 nodes.
Association group 4 supports 4 nodes.
| Command Class | Comment |
|---|---|
| COMMAND_CLASS_NO_OPERATION_V1 | |
| COMMAND_CLASS_BASIC_V1 | |
| COMMAND_CLASS_SWITCH_BINARY_V1 | |
| COMMAND_CLASS_SWITCH_MULTILEVEL_V3 | Linked to BASIC |
| COMMAND_CLASS_SWITCH_ALL_V1 | |
| COMMAND_CLASS_SENSOR_MULTILEVEL_V3 | |
| COMMAND_CLASS_METER_V3 | |
| COMMAND_CLASS_MULTI_CHANNEL_V2 | |
| COMMAND_CLASS_CONFIGURATION_V1 | |
| COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
| COMMAND_CLASS_POWERLEVEL_V1 | |
| COMMAND_CLASS_ASSOCIATION_V1 | |
| COMMAND_CLASS_VERSION_V1 |
| Command Class | Comment |
|---|---|
| COMMAND_CLASS_BASIC_V1 | |
| COMMAND_CLASS_SENSOR_BINARY_V1 | Linked to BASIC |
| Command Class | Comment |
|---|---|
| COMMAND_CLASS_BASIC_V1 | |
| COMMAND_CLASS_SENSOR_BINARY_V1 | Linked to BASIC |