This describes the Z-Wave device TZ08, manufactured by TKB Home with the thing type UID of tkb_tz08_00_000.
The device is in the category of Blinds, defining Roller shutters, window blinds, etc..
The TZ08 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
The in-wall Roller Shutter Controller is designed to switch rise/lower roller shutter connected to its terminals using radio waves, controllers and a push button directly connected to this Roller Controller.
This in-wall Roller Shutter Controller is a transceiver which is a Z-WaveTM enabled device and is fully compatible with any Z-WaveTM enabled network. Slim design let the Controller can easily hide itself into the wall box and that will be good for the house decoration.
Pressing Include button three times within 1.5 seconds will enter inclusion mode.
Pressing Include button three times within 1.5 seconds will enter exclusion mode.
The following table summarises the channels available for the TZ08 -:
| Channel Name | Channel ID | Channel Type | Category | Item Type |
|---|---|---|---|---|
| Switch | switch_binary | switch_binary | Switch | Switch |
| Dimmer | switch_dimmer | switch_dimmer | DimmableLight | Dimmer |
| Electric meter (amps) | meter_current | meter_current | Energy | Number |
| Electric meter (volts) | meter_voltage | meter_voltage | Energy | Number |
| Electric meter (power factor) | meter_powerfactor | meter_powerfactor | Energy | Number |
| Electric meter (watts) | meter_watts | meter_watts | Energy | Number |
| Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number |
| Alarm | alarm_general | alarm_general | Alarm | Switch |
Switch the power on and off.
The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer channel is of type switch_dimmer and supports the Dimmer item and is in the DimmableLight category.
Indicates the instantaneous current consumption.
The meter_current channel is of type meter_current and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous voltage.
The meter_voltage channel is of type meter_voltage and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power factor.
The meter_powerfactor channel is of type meter_powerfactor and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power consumption.
The meter_watts channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.
Indicates if an alarm is triggered.
The alarm_general channel is of type alarm_general and supports the Switch item and is in the Alarm category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch item type -:
| Value | Label |
|---|---|
| OFF | OK |
| ON | Alarm |
The following table provides a summary of the 4 configuration parameters available in the TZ08. Detailed information on each parameter can be found in the sections below.
| Param | Name | Description |
|---|---|---|
| 1 | Watt meter report period | |
| 2 | KWh meter report period | |
| 3 | Watt load caution threshold | |
| 4 | KWh load caution threshold |
Values in the range 1 to 32767 may be set.
The manufacturer defined default value is 720.
This parameter has the configuration ID config_1_2 and is of type INTEGER.
Values in the range 1 to 32767 may be set.
The manufacturer defined default value is 6.
This parameter has the configuration ID config_2_2 and is of type INTEGER.
Values in the range 10 to 1100 may be set.
The manufacturer defined default value is 1100.
This parameter has the configuration ID config_3_2 and is of type INTEGER.
Values in the range 1 to 10000 may be set.
The manufacturer defined default value is 10000.
This parameter has the configuration ID config_4_2 and is of type INTEGER.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The TZ08 supports 1 association group.
Association group 1 supports 1 node.
| Command Class | Comment |
|---|---|
| COMMAND_CLASS_NO_OPERATION_V1 | |
| COMMAND_CLASS_BASIC_V1 | |
| COMMAND_CLASS_SWITCH_BINARY_V1 | |
| COMMAND_CLASS_SWITCH_MULTILEVEL_V3 | |
| COMMAND_CLASS_SCENE_ACTIVATION_V1 | |
| COMMAND_CLASS_METER_V3 | |
| COMMAND_CLASS_CONFIGURATION_V1 | |
| COMMAND_CLASS_ALARM_V1 | |
| COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
| COMMAND_CLASS_ASSOCIATION_V1 | |
| COMMAND_CLASS_VERSION_V1 |