This describes the Z-Wave device TZ88, manufactured by TKB Home with the thing type UID of tkb_tz88_00_000.
The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.
The TZ88 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
This plug-in ON/OFF switch TZ88 is a security enabled wireless switch, based on Z-Wave Plus technology. Z-Wave Plus™ enabled devices displaying the Z-Wave Plus™ logo can also be used with it regardless of the manufacturer, and can also be used in other manufacturer’s Z-Wave™ enabled network
Pressing On/Off button three times within 2 seconds will enter inclusion mode.
Pressing On/Off button three times within 2 seconds will enter exclusion mode.
The following table summarises the channels available for the TZ88 -:
| Channel Name | Channel ID | Channel Type | Category | Item Type |
|---|---|---|---|---|
| Switch | switch_binary | switch_binary | Switch | Switch |
| Electric meter (power factor) | meter_powerfactor | meter_powerfactor | Energy | Number |
| Electric meter (amps) | meter_current | meter_current | Energy | Number |
| Electric meter (watts) | meter_watts | meter_watts | Energy | Number |
| Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number |
| Electric meter (volts) | meter_voltage | meter_voltage | Energy | Number |
Switch the power on and off.
The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.
Indicates the instantaneous power factor.
The meter_powerfactor channel is of type meter_powerfactor and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous current consumption.
The meter_current channel is of type meter_current and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power consumption.
The meter_watts channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous voltage.
The meter_voltage channel is of type meter_voltage and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.
The following table provides a summary of the 4 configuration parameters available in the TZ88. Detailed information on each parameter can be found in the sections below.
| Param | Name | Description |
|---|---|---|
| 1 | Watt meter report interval (5s) | Interval (x5 seconds) to send out watt meter report |
| 2 | KWH Meter Report Interval (10min) | Interval (x10 minutes) to send out KWH Meter Report |
| 3 | Threshold for Load Caution (10mA) | Threshold (x0.01A) of current for Load Caution |
| 4 | Threshold of KWh for Load Caution | |
| Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Interval (x5 seconds) to send out watt meter report
Values in the range 1 to 32767 may be set.
The manufacturer defined default value is 720.
This parameter has the configuration ID config_1_2 and is of type INTEGER.
Interval (x10 minutes) to send out KWH Meter Report
Values in the range 1 to 32767 may be set.
The manufacturer defined default value is 6.
This parameter has the configuration ID config_2_2 and is of type INTEGER.
Threshold (x0.01A) of current for Load Caution
Values in the range 1 to 1300 may be set.
The manufacturer defined default value is 1300.
This parameter has the configuration ID config_3_2 and is of type INTEGER.
Values in the range 1 to 10000 may be set.
The manufacturer defined default value is 10000.
This parameter has the configuration ID config_4_2 and is of type INTEGER.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
| Value | Description |
|---|---|
| 0 | Exclude from All On and All Off groups |
| 1 | Include in All On group |
| 2 | Include in All Off group |
| 255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode and is of type INTEGER.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The TZ88 supports 1 association group.
Association group 1 supports 1 node.
| Command Class | Comment |
|---|---|
| COMMAND_CLASS_NO_OPERATION_V1 | |
| COMMAND_CLASS_BASIC_V1 | |
| COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
| COMMAND_CLASS_SWITCH_ALL_V1 | |
| COMMAND_CLASS_METER_V3 | |
| COMMAND_CLASS_CONFIGURATION_V1 | |
| COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
| COMMAND_CLASS_ASSOCIATION_V1 | |
| COMMAND_CLASS_VERSION_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.