| layout | documentation |
|---|---|
| title | Schlage - ZWave |
{% include base.html %}
This describes the Z-Wave device Schlage, manufactured by Trane Corporation with the thing type UID of trane_le130_00_000.
The device is in the category of Remote Control, defining Any portable or hand-held device that controls the status of something, e.g. remote control, keyfob etc..
The Schlage supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
LE130 REMOTE CONTROLLER FOR SPLIT-TYPE AIR CONDITIONERS
See user guide for IDs specific to each unit
- Power on the remote
- Put the primary controller into inclusion mode (If you don’t know how to do this, refer to its manual).
- Hold down the Fan/Set buttons for 3 seconds
- If the inclusion is success, the LED will flash three times and the zwave wireless icon will light on the screen
- Power on the remote
- Put the primary controller into excluison mode (If you don’t know how to do this, refer to its manual).
- Hold down the Fan/Set buttons for 3 seconds
- If the exclusion is success, the LED will flash three times and the zwave wireless icon will go out on the screen
The following table summarises the channels available for the Schlage -:
| Channel Name | Channel ID | Channel Type | Category | Item Type |
|---|---|---|---|---|
| Sensor (temperature) | sensor_temperature | sensor_temperature | Temperature | Number:Temperature |
| Thermostat mode | thermostat_mode | thermostat_mode | Temperature | Number |
| Setpoint (heating) | thermostat_setpoint | thermostat_setpoint | Heating | Number:Temperature |
| Setpoint (cooling) | thermostat_setpoint | thermostat_setpoint | Heating | Number:Temperature |
| Thermostat fan mode | thermostat_fanmode | thermostat_fanmode | ||
| Battery Level | battery-level | system.battery_level | Battery | Number |
Indicates the current temperature.
The sensor_temperature channel is of type sensor_temperature and supports the Number:Temperature item and is in the Temperature category.
Sets the thermostat.
The thermostat_mode channel is of type thermostat_mode and supports the Number item and is in the Temperature category.
The following state translation is provided for this channel to the Number item type -:
| Value | Label |
|---|---|
| 0 | Off |
| 1 | Heat |
| 2 | Cool |
| 3 | Auto |
| 4 | Aux Heat |
| 5 | Resume |
| 6 | Fan Only |
| 7 | Furnace |
| 8 | Dry Air |
| 9 | Moist Air |
| 10 | Auto Changeover |
| 11 | Heat Economy |
| 12 | Cool Economy |
| 13 | Away |
Sets the thermostat setpoint.
The thermostat_setpoint channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.
Sets the thermostat setpoint.
The thermostat_setpoint channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.
Channel type information on this channel is not found.
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The system.battery-level channel is of type system.battery-level and supports the Number item and is in the Battery category.
This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.
The device has no configuration parameters defined.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The device does not support associations.
| Command Class | Comment |
|---|---|
| COMMAND_CLASS_NO_OPERATION_V1 | |
| COMMAND_CLASS_BASIC_V1 | |
| COMMAND_CLASS_SENSOR_MULTILEVEL_V1 | |
| COMMAND_CLASS_THERMOSTAT_MODE_V1 | |
| COMMAND_CLASS_THERMOSTAT_SETPOINT_V1 | |
| COMMAND_CLASS_THERMOSTAT_FAN_MODE_V1 | |
| COMMAND_CLASS_CONFIGURATION_V1 | |
| COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
| COMMAND_CLASS_BATTERY_V1 | |
| COMMAND_CLASS_VERSION_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.