| layout | documentation |
|---|---|
| title | Trane XR524 - ZWave |
{% include base.html %}
This describes the Z-Wave device Trane XR524, manufactured by Trane Corporation with the thing type UID of trane_xr524_00_000.
The device is in the category of HVAC, defining Air condition devices, Fans.
The Trane XR524 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
The Trane 524 Touchscreen Comfort Control is compatible with single and multistage forced air systems, including:
- Gas furnace systems
- Oil furnace systems
- Electric furnace systems
- Heat pump systems
- Air conditioning systems
- Press MENU on the 524 Control.
- Press NEXT to advance to the Z-WAVE menu.
- Press SELECT
- Press MENU on the 524 Control.
- Press NEXT to scroll to Z-WAVE screen then press SELECT.
- Press YES to exclude the control
The following table summarises the channels available for the Trane XR524 -:
| Channel Name | Channel ID | Channel Type | Category | Item Type |
|---|---|---|---|---|
| Sensor (temperature) | sensor_temperature | sensor_temperature | Temperature | Number:Temperature |
| Thermostat mode | thermostat_mode | thermostat_mode | Temperature | Number |
| Operating State | thermostat_state | thermostat_state | Temperature | Number |
| Setpoint (heating) | thermostat_setpoint | thermostat_setpoint | Heating | Number:Temperature |
| Setpoint (cooling) | thermostat_setpoint | thermostat_setpoint | Heating | Number:Temperature |
| Thermostat fan mode | thermostat_fanmode | thermostat_fanmode | ||
| Thermostat fan state | thermostat_fanstate | thermostat_fanstate |
Indicates the current temperature.
The sensor_temperature channel is of type sensor_temperature and supports the Number:Temperature item and is in the Temperature category.
Sets the thermostat.
The thermostat_mode channel is of type thermostat_mode and supports the Number item and is in the Temperature category.
The following state translation is provided for this channel to the Number item type -:
| Value | Label |
|---|---|
| 0 | Off |
| 1 | Heat |
| 2 | Cool |
| 3 | Auto |
| 4 | Aux Heat |
| 5 | Resume |
| 6 | Fan Only |
| 7 | Furnace |
| 8 | Dry Air |
| 9 | Moist Air |
| 10 | Auto Changeover |
| 11 | Heat Economy |
| 12 | Cool Economy |
| 13 | Away |
Sets the thermostat operating state.
The thermostat_state channel is of type thermostat_state and supports the Number item and is in the Temperature category.
The following state translation is provided for this channel to the Number item type -:
| Value | Label |
|---|---|
| 0 | Idle |
| 1 | Heating |
| 2 | Cooling |
| 3 | Fan Only |
| 4 | Pending Heat |
| 5 | Pending Cool |
| 6 | Vent / Economiser |
Sets the thermostat setpoint.
The thermostat_setpoint channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.
Sets the thermostat setpoint.
The thermostat_setpoint channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.
Channel type information on this channel is not found.
Channel type information on this channel is not found.
The following table provides a summary of the 59 configuration parameters available in the Trane XR524. Detailed information on each parameter can be found in the sections below.
| Param | Name | Description |
|---|---|---|
| 1 | System Type | System Type |
| 2 | Fan Type | Fan Type |
| 3 | Change Over Type | Change Over Type |
| 4 | Units | Units |
| 9 | Display Lock | Display Lock |
| 10 | Minimum Off Time | Minimum Off Time |
| 11 | Minimum Run Time | Minimum Run Time |
| 12 | Heating Delta Stage 1 ON | Heating Delta Stage 1 ON |
| 13 | Heating Delta Stage 1 OFF | Heating Delta Stage 1 OFF |
| 14 | Heating Delta Stage 2 ON | Heating Delta Stage 2 ON |
| 15 | Heating Delta Stage 2 OFF | Heating Delta Stage 2 OFF |
| 16 | Heating Delta Stage 3 ON | Heating Delta Stage 3 ON |
| 17 | Heating Delta Stage 3 OFF | Heating Delta Stage 3 OFF |
| 18 | Cooling Delta Stage 1 ON | Cooling Delta Stage 1 ON |
| 19 | Cooling Delta Stage 1 OFF | Cooling Delta Stage 1 OFF |
| 20 | Cooling Delta Stage 2 ON | Cooling Delta Stage 2 ON |
| 21 | Cooling Delta Stage 2 OFF | Cooling Delta Stage 2 OFF |
| 24 | H/C Delta | H/C Delta |
| 25 | SetBack Mode | SetBack Mode |
| 29 | ESM Setpoint--Heating | ESM Setpoint--Heating |
| 30 | ESM Setpoint--Cooling | ESM Setpoint--Cooling |
| 75 | Fan ON Time | Fan ON Time |
| 76 | Fan OFF Time | Fan OFF Time |
| 77 | 2nd Stage Heat Enable | 2nd Stage Heat Enable |
| 78 | Aux Heat Enable | Aux Heat Enable |
| 79 | 2nd Stage Cool Enable | 2nd Stage Cool Enable |
| 132 | Run Schedule | Run Schedule |
| 137 | Backlight Timeout | Backlight Timeout |
| 141 | Screen Timeout | Screen Timeout |
| 143 | Sensor (Internal) Offset | Sensor (Internal) Offset |
| 148 | Screen Contrast | Screen Contrast |
| 185 | Schedule Enable | Schedule Enable |
| 228 | Schedule Sun-1 | Schedule Sun-1 |
| 229 | Schedule Sun-2 | Schedule Sun-2 |
| 230 | Schedule Sun-3 | Schedule Sun-3 |
| 231 | Schedule Sun-4 | Schedule Sun-4 |
| 232 | Schedule Mon-1 | Schedule Mon-1 |
| 233 | Schedule Mon-2 | Schedule Mon-2 |
| 234 | Schedule Mon-3 | Schedule Mon-3 |
| 235 | Schedule Mon-4 | Schedule Mon-4 |
| 236 | Schedule Tue-1 | Schedule Tue-1 |
| 237 | Schedule Tue-2 | Schedule Tue-2 |
| 238 | Schedule Tue-3 | Schedule Tue-3 |
| 239 | Schedule Tue-4 | Schedule Tue-4 |
| 240 | Schedule Wed-1 | Schedule Wed-1 |
| 241 | Schedule Wed-2 | Schedule Wed-2 |
| 242 | Schedule Wed-3 | Schedule Wed-3 |
| 243 | Schedule Wed-4 | Schedule Wed-4 |
| 244 | Schedule Thu-1 | Schedule Thu-1 |
| 246 | Schedule Thu-3 | Schedule Thu-3 |
| 247 | Schedule Thu-4 | Schedule Thu-4 |
| 248 | Schedule Fri-1 | Schedule Fri-1 |
| 249 | Schedule Fri-2 | Schedule Fri-2 |
| 250 | Schedule Fri-3 | Schedule Fri-3 |
| 251 | Schedule Fri-4 | Schedule Fri-4 |
| 252 | Schedule Sat-1 | Schedule Sat-1 |
| 253 | Schedule Sat-2 | Schedule Sat-2 |
| 254 | Schedule Sat-3 | Schedule Sat-3 |
| 255 | Schedule Sat-4 | Schedule Sat-4 |
System Type This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -:
| Value | Description |
|---|---|
| 0 | Gas/Electric |
| 1 | HeatPump |
The manufacturer defined default value is 0 (Gas/Electric).
This parameter has the configuration ID config_1_1 and is of type INTEGER.
Fan Type This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -:
| Value | Description |
|---|---|
| 0 | Gas |
| 1 | Electric |
The manufacturer defined default value is 0 (Gas).
This parameter has the configuration ID config_2_1 and is of type INTEGER.
Change Over Type This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -:
| Value | Description |
|---|---|
| 0 | w/Cool |
| 1 | w/Heat |
The manufacturer defined default value is 0 (w/Cool).
This parameter has the configuration ID config_3_1 and is of type INTEGER.
Units
The following option values may be configured -:
| Value | Description |
|---|---|
| 0 | Celsius |
| 1 | Fahrenheit |
The manufacturer defined default value is 1 (Fahrenheit).
This parameter has the configuration ID config_4_1 and is of type INTEGER.
Display Lock
The following option values may be configured -:
| Value | Description |
|---|---|
| 0 | Unlocked |
| 1 | Locked |
The manufacturer defined default value is 0 (Unlocked).
This parameter has the configuration ID config_9_1 and is of type INTEGER.
Minimum Off Time Sets the minimum off time before another heating/cooling cycle can begin to provide compressor short cycle protection. The thermostat screen will display WAIT when minimum off time is being enforced.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 5 to 9 may be set.
The manufacturer defined default value is 5.
This parameter has the configuration ID config_10_1 and is of type INTEGER.
Minimum Run Time Sets the minimum run time before a heating/cooling cycle can turn off to prevent rapid cycling. Thermostat screen will display "Cool ON" or "Heat ON" while the minimum run time is being enforced.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 1 to 9 may be set.
The manufacturer defined default value is 6.
This parameter has the configuration ID config_11_1 and is of type INTEGER.
Heating Delta Stage 1 ON Sets the delta from setpoint that stage 1 heating starts.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 1 to 8 may be set.
The manufacturer defined default value is 1.
This parameter has the configuration ID config_12_1 and is of type INTEGER.
Heating Delta Stage 1 OFF Sets the delta from setpoint that stage 1 heating stops. Stage 1 turns off at setpoint minus (-) Delta Stage 1.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 8 may be set.
The manufacturer defined default value is 0.
This parameter has the configuration ID config_13_1 and is of type INTEGER.
Heating Delta Stage 2 ON Sets the delta from setpoint that stage 2 heating starts.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 1 to 8 may be set.
The manufacturer defined default value is 2.
This parameter has the configuration ID config_14_1 and is of type INTEGER.
Heating Delta Stage 2 OFF Sets the delta from setpoint that stage 2 heating stops. Stage 1 turns off at setpoint minus (-) Delta Stage 2.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 8 may be set.
The manufacturer defined default value is 0.
This parameter has the configuration ID config_15_1 and is of type INTEGER.
Heating Delta Stage 3 ON Sets the delta from setpoint that stage 3 heating starts.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 1 to 8 may be set.
The manufacturer defined default value is 3.
This parameter has the configuration ID config_16_1 and is of type INTEGER.
Heating Delta Stage 3 OFF Sets the delta from setpoint that stage 3 heating stops. Stage 1 turns off at setpoint minus (-) Delta Stage 3This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 8 may be set.
The manufacturer defined default value is 0.
This parameter has the configuration ID config_17_1 and is of type INTEGER.
Cooling Delta Stage 1 ON Sets the delta from setpoint that stage 1 cooling starts.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 1 to 8 may be set.
The manufacturer defined default value is 1.
This parameter has the configuration ID config_18_1 and is of type INTEGER.
Cooling Delta Stage 1 OFF Sets the delta from setpoint that stage 1 cooling stops. Stage 1 turns off at setpoint minus (-) Delta Stage 1.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 8 may be set.
The manufacturer defined default value is 0.
This parameter has the configuration ID config_19_1 and is of type INTEGER.
Cooling Delta Stage 2 ON Sets the delta from setpoint that stage 2 cooling starts.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 1 to 8 may be set.
The manufacturer defined default value is 2.
This parameter has the configuration ID config_20_1 and is of type INTEGER.
Cooling Delta Stage 2 OFF Sets the delta from setpoint that stage 2 cooling stops. Stage 1 turns off at setpoint minus (-) Delta Stage 2. Values in the range 0 to 8 may be set.
The manufacturer defined default value is 0.
This parameter has the configuration ID config_21_1 and is of type INTEGER.
H/C Delta
Sets the minimum separation between the heating and cooling setpoints. Attempts to lower the cooling below the heating setpoint by this amount will PUSH the heating setpoint down to maintain this separation. Same for setting the heating setpoint above the cooling setpoint, it will PUSH the cooling setpoint up to maintain this separation.
Settings in F.
Values in the range 3 to 15 may be set.
The manufacturer defined default value is 3.
This parameter has the configuration ID config_24_1 and is of type INTEGER.
SetBack Mode 0 = No Setback, 1 = Setback, 2 if ESM The following option values may be configured -:
| Value | Description |
|---|---|
| 0 | No Setback |
| 1 | Setback |
| 2 | ESM |
The manufacturer defined default value is 0 (No Setback).
This parameter has the configuration ID config_25_1 and is of type INTEGER.
ESM Setpoint--Heating
Energy Saving Mode (ESM) Setpoints are the setpoints used when the Energy Saving Mode schedule is selected in the Schedule Mode screen (or via Z-Wave control).
Setting in F.
Values in the range 0 to 100 may be set.
The manufacturer defined default value is 65.
This parameter has the configuration ID config_29_1 and is of type INTEGER.
ESM Setpoint--Cooling Energy Saving Mode (ESM) Setpoints are the setpoints used when the Energy Saving Mode schedule is selected in the Schedule Mode screen (or via Z-Wave control). Values in the range 0 to 100 may be set.
The manufacturer defined default value is 80.
This parameter has the configuration ID config_30_1 and is of type INTEGER.
Fan ON Time The fan cycler function cycles the HVAC system fan for an ON period followed by an OFF period continuously. Used to provide minimum air ventilation requirements.
When the Fan ON time is set to a value greater than 0, an additional Cycler Fan mode is present when pressing the FAN button on the thermostat. Values in the range 0 to 120 may be set.
The manufacturer defined default value is 0.
This parameter has the configuration ID config_75_1 and is of type INTEGER.
Fan OFF Time The fan cycler function cycles the HVAC system fan for an ON period followed by an OFF period continuously. Used to provide minimum air ventilation requirements.
When the Fan ON time is set to a value greater than 0, an additional Cycler Fan mode is present when pressing the FAN button on the thermostat. Values in the range 10 to 120 may be set.
The manufacturer defined default value is 10.
This parameter has the configuration ID config_76_1 and is of type INTEGER.
2nd Stage Heat Enable
The following option values may be configured -:
| Value | Description |
|---|---|
| 0 | no 2nd stage heat |
| 1 | 2nd stage heat |
The manufacturer defined default value is 0 (no 2nd stage heat).
This parameter has the configuration ID config_77_1 and is of type INTEGER.
Aux Heat Enable
The following option values may be configured -:
| Value | Description |
|---|---|
| 0 | no aux heat |
| 1 | aux heat enabled |
The manufacturer defined default value is 0 (no aux heat).
This parameter has the configuration ID config_78_1 and is of type INTEGER.
2nd Stage Cool Enable
The following option values may be configured -:
| Value | Description |
|---|---|
| 0 | no 2nd stage cool |
| 1 | 2nd stage cool |
The manufacturer defined default value is 0 (no 2nd stage cool).
This parameter has the configuration ID config_79_1 and is of type INTEGER.
Run Schedule Set to 1 if running schedule (RUN is displayed on the thermostat screen). The following option values may be configured -:
| Value | Description |
|---|---|
| 0 | not running schedule |
| 1 | running schedule |
The manufacturer defined default value is 0 (not running schedule).
This parameter has the configuration ID config_132_1 and is of type INTEGER.
Backlight Timeout Backlight Timeout is the time (in seconds) from the last button press to the backlight going out.
The time-out can be set between 0 and 120 seconds.
When set to 0, the backlight will remain always on. Values in the range 0 to 120 may be set.
The manufacturer defined default value is 30.
This parameter has the configuration ID config_137_1 and is of type INTEGER.
Screen Timeout This is the time before any screen reverts to the Minimized Screen (temperature display only), after you stop pushing buttons.
Minimized Screen feature is disabled by setting this time to 0 Values in the range 0 to 120 may be set.
The manufacturer defined default value is 0.
This parameter has the configuration ID config_141_1 and is of type INTEGER.
Sensor (Internal) Offset The internal temperature sensor can be calibrated to report values different from its actual reading. The offset can range from -7 degrees to +7 degrees.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range -7 to 7 may be set.
The manufacturer defined default value is 0.
This parameter has the configuration ID config_143_1 and is of type INTEGER.
Screen Contrast The Screen Contrast sets the contrast level of the LCD display.
The contrast can be set between 0 and 20. If the display is too light, use a higher number. If dark lines appear on the screen, use a lower number Values in the range 0 to 20 may be set.
The manufacturer defined default value is 10.
This parameter has the configuration ID config_148_1 and is of type INTEGER.
Schedule Enable When enabled (set to 1), the local thermostat's scheduler function is enabled.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 1 may be set.
The manufacturer defined default value is 0.
This parameter has the configuration ID config_185_1 and is of type INTEGER.
Schedule Sun-1 This value holds information about the first schedule setpoints for Sundays.
- Byte 1: Hour (0-23)
- Byte 2: Minute (0-59)
- Byte 3: Heat Setpoint (degrees)
- Byte 4: Cool Setpoint (degrees)
Default: 0x06004643 06:00AM 70F / 67F
0x06001519 06:00AM 21C / 25CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0.
This parameter has the configuration ID config_228_4 and is of type INTEGER.
Schedule Sun-2 This value holds information about the second schedule setpoints for Sundays.
- Byte 1: Hour (0-23)
- Byte 2: Minute (0-59)
- Byte 3: Heat Setpoint (degrees)
- Byte 4: Cool Setpoint (degrees)
Default: 0x08003e55 08:00AM 62F / 85F
0x0800101d 08:00AM 16C / 29CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0.
This parameter has the configuration ID config_229_4 and is of type INTEGER.
Schedule Sun-3 This value holds information about the third schedule setpoints for Sundays.
- Byte 1: Hour (0-23)
- Byte 2: Minute (0-59)
- Byte 3: Heat Setpoint (degrees)
- Byte 4: Cool Setpoint (degrees)
Default: 0x1200464e 06:00PM 70F / 78F
0x12001519 06:00PM 21C / 25CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0.
This parameter has the configuration ID config_230_4 and is of type INTEGER.
Schedule Sun-4 This value holds information about the fourth schedule setpoints for Sundays.
- Byte 1: Hour (0-23)
- Byte 2: Minute (0-59)
- Byte 3: Heat Setpoint (degrees)
- Byte 4: Cool Setpoint (degrees)
Default: 0x16003e52 10:00PM 62F / 82F
0x1600101b 10:00PM 16C / 27CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0.
This parameter has the configuration ID config_231_4 and is of type INTEGER.
Schedule Mon-1 This value holds information about the first schedule setpoints for Mondays.
- Byte 1: Hour (0-23)
- Byte 2: Minute (0-59)
- Byte 3: Heat Setpoint (degrees)
- Byte 4: Cool Setpoint (degrees)
Default: 0x06004643 06:00AM 70F / 67F
0x06001519 06:00AM 21C / 25CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0.
This parameter has the configuration ID config_232_4 and is of type INTEGER.
Schedule Mon-2 This value holds information about the second schedule setpoints for Mondays.
- Byte 1: Hour (0-23)
- Byte 2: Minute (0-59)
- Byte 3: Heat Setpoint (degrees)
- Byte 4: Cool Setpoint (degrees)
Default: 0x08003e55 08:00AM 62F / 85F
0x0800101d 08:00AM 16C / 29CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0.
This parameter has the configuration ID config_233_4 and is of type INTEGER.
Schedule Mon-3 This value holds information about the third schedule setpoints for Mondays.
- Byte 1: Hour (0-23)
- Byte 2: Minute (0-59)
- Byte 3: Heat Setpoint (degrees)
- Byte 4: Cool Setpoint (degrees)
Default: 0x1200464e 06:00PM 70F / 78F
0x12001519 06:00PM 21C / 25CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0.
This parameter has the configuration ID config_234_4 and is of type INTEGER.
Schedule Mon-4 This value holds information about the fourth schedule setpoints for Mondays.
- Byte 1: Hour (0-23)
- Byte 2: Minute (0-59)
- Byte 3: Heat Setpoint (degrees)
- Byte 4: Cool Setpoint (degrees)
Default: 0x16003e52 10:00PM 62F / 82F
0x1600101b 10:00PM 16C / 27CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0.
This parameter has the configuration ID config_235_4 and is of type INTEGER.
Schedule Tue-1 This value holds information about the first schedule setpoints for Tuesdays.
- Byte 1: Hour (0-23)
- Byte 2: Minute (0-59)
- Byte 3: Heat Setpoint (degrees)
- Byte 4: Cool Setpoint (degrees)
Default: 0x06004643 06:00AM 70F / 67F
0x06001519 06:00AM 21C / 25CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0.
This parameter has the configuration ID config_236_4 and is of type INTEGER.
Schedule Tue-2 This value holds information about the second schedule setpoints for Tuesdays.
- Byte 1: Hour (0-23)
- Byte 2: Minute (0-59)
- Byte 3: Heat Setpoint (degrees)
- Byte 4: Cool Setpoint (degrees)
Default: 0x08003e55 08:00AM 62F / 85F
0x0800101d 08:00AM 16C / 29CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0.
This parameter has the configuration ID config_237_4 and is of type INTEGER.
Schedule Tue-3 This value holds information about the third schedule setpoints for Tuesdays.
- Byte 1: Hour (0-23)
- Byte 2: Minute (0-59)
- Byte 3: Heat Setpoint (degrees)
- Byte 4: Cool Setpoint (degrees)
Default: 0x1200464e 06:00PM 70F / 78F
0x12001519 06:00PM 21C / 25CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0.
This parameter has the configuration ID config_238_4 and is of type INTEGER.
Schedule Tue-4 This value holds information about the fourth schedule setpoints for Tuesdays.
- Byte 1: Hour (0-23)
- Byte 2: Minute (0-59)
- Byte 3: Heat Setpoint (degrees)
- Byte 4: Cool Setpoint (degrees)
Default: 0x16003e52 10:00PM 62F / 82F
0x1600101b 10:00PM 16C / 27CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0.
This parameter has the configuration ID config_239_4 and is of type INTEGER.
Schedule Wed-1 This value holds information about the first schedule setpoints for Wednesdays.
- Byte 1: Hour (0-23)
- Byte 2: Minute (0-59)
- Byte 3: Heat Setpoint (degrees)
- Byte 4: Cool Setpoint (degrees)
Default: 0x06004643 06:00AM 70F / 67F
0x06001519 06:00AM 21C / 25CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0.
This parameter has the configuration ID config_240_4 and is of type INTEGER.
Schedule Wed-2 This value holds information about the second schedule setpoints for Wednesdays.
- Byte 1: Hour (0-23)
- Byte 2: Minute (0-59)
- Byte 3: Heat Setpoint (degrees)
- Byte 4: Cool Setpoint (degrees)
Default: 0x08003e55 08:00AM 62F / 85F
0x0800101d 08:00AM 16C / 29CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0.
This parameter has the configuration ID config_241_4 and is of type INTEGER.
Schedule Wed-3 This value holds information about the third schedule setpoints for Wednesdays.
- Byte 1: Hour (0-23)
- Byte 2: Minute (0-59)
- Byte 3: Heat Setpoint (degrees)
- Byte 4: Cool Setpoint (degrees)
Default: 0x1200464e 06:00PM 70F / 78F
0x12001519 06:00PM 21C / 25CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0.
This parameter has the configuration ID config_242_4 and is of type INTEGER.
Schedule Wed-4 This value holds information about the fourth schedule setpoints for Wednesdays.
- Byte 1: Hour (0-23)
- Byte 2: Minute (0-59)
- Byte 3: Heat Setpoint (degrees)
- Byte 4: Cool Setpoint (degrees)
Default: 0x16003e52 10:00PM 62F / 82F
0x1600101b 10:00PM 16C / 27CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0.
This parameter has the configuration ID config_243_4 and is of type INTEGER.
Schedule Thu-1 This value holds information about the second schedule setpoints for Thursdays.
- Byte 1: Hour (0-23)
- Byte 2: Minute (0-59)
- Byte 3: Heat Setpoint (degrees)
- Byte 4: Cool Setpoint (degrees)
Default: 0x08003e55 08:00AM 62F / 85F
0x0800101d 08:00AM 16C / 29CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0.
This parameter has the configuration ID config_244_4 and is of type INTEGER.
Schedule Thu-3 This value holds information about the third schedule setpoints for Thursdays.
- Byte 1: Hour (0-23)
- Byte 2: Minute (0-59)
- Byte 3: Heat Setpoint (degrees)
- Byte 4: Cool Setpoint (degrees)
Default: 0x1200464e 06:00PM 70F / 78F
0x12001519 06:00PM 21C / 25CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0.
This parameter has the configuration ID config_246_4 and is of type INTEGER.
Schedule Thu-4 This value holds information about the fourth schedule setpoints for Thursdays.
- Byte 1: Hour (0-23)
- Byte 2: Minute (0-59)
- Byte 3: Heat Setpoint (degrees)
- Byte 4: Cool Setpoint (degrees)
Default: 0x16003e52 10:00PM 62F / 82F
0x1600101b 10:00PM 16C / 27CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0.
This parameter has the configuration ID config_247_4 and is of type INTEGER.
Schedule Fri-1 This value holds information about the first schedule setpoints for Fridays.
- Byte 1: Hour (0-23)
- Byte 2: Minute (0-59)
- Byte 3: Heat Setpoint (degrees)
- Byte 4: Cool Setpoint (degrees)
Default: 0x06004643 06:00AM 70F / 67F
0x06001519 06:00AM 21C / 25CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0.
This parameter has the configuration ID config_248_4 and is of type INTEGER.
Schedule Fri-2 This value holds information about the second schedule setpoints for Fridays.
- Byte 1: Hour (0-23)
- Byte 2: Minute (0-59)
- Byte 3: Heat Setpoint (degrees)
- Byte 4: Cool Setpoint (degrees)
Default: 0x08003e55 08:00AM 62F / 85F
0x0800101d 08:00AM 16C / 29CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0.
This parameter has the configuration ID config_249_4 and is of type INTEGER.
Schedule Fri-3 This value holds information about the fourth schedule setpoints for Fridays.
- Byte 1: Hour (0-23)
- Byte 2: Minute (0-59)
- Byte 3: Heat Setpoint (degrees)
- Byte 4: Cool Setpoint (degrees)
Default: 0x16003e52 10:00PM 62F / 82F
0x1600101b 10:00PM 16C / 27CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0.
This parameter has the configuration ID config_250_4 and is of type INTEGER.
Schedule Fri-4 This value holds information about the fourth schedule setpoints for Fridays.
- Byte 1: Hour (0-23)
- Byte 2: Minute (0-59)
- Byte 3: Heat Setpoint (degrees)
- Byte 4: Cool Setpoint (degrees)
Default: 0x16003e52 10:00PM 62F / 82F
0x1600101b 10:00PM 16C / 27CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0.
This parameter has the configuration ID config_251_4 and is of type INTEGER.
Schedule Sat-1 This value holds information about the first schedule setpoints for Saturdays.
- Byte 1: Hour (0-23)
- Byte 2: Minute (0-59)
- Byte 3: Heat Setpoint (degrees)
- Byte 4: Cool Setpoint (degrees)
Default: 0x06004643 06:00AM 70F / 67F
0x06001519 06:00AM 21C / 25CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0.
This parameter has the configuration ID config_252_4 and is of type INTEGER.
Schedule Sat-2 This value holds information about the second schedule setpoints for Saturdays.
- Byte 1: Hour (0-23)
- Byte 2: Minute (0-59)
- Byte 3: Heat Setpoint (degrees)
- Byte 4: Cool Setpoint (degrees)
Default: 0x08003e55 08:00AM 62F / 85F
0x0800101d 08:00AM 16C / 29CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0.
This parameter has the configuration ID config_253_4 and is of type INTEGER.
Schedule Sat-3 This value holds information about the third schedule setpoints for Saturdays.
- Byte 1: Hour (0-23)
- Byte 2: Minute (0-59)
- Byte 3: Heat Setpoint (degrees)
- Byte 4: Cool Setpoint (degrees)
Default: 0x1200464e 06:00PM 70F / 78F
0x12001519 06:00PM 21C / 25CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0.
This parameter has the configuration ID config_254_4 and is of type INTEGER.
Schedule Sat-4 This value holds information about the fourth schedule setpoints for Saturdays.
- Byte 1: Hour (0-23)
- Byte 2: Minute (0-59)
- Byte 3: Heat Setpoint (degrees)
- Byte 4: Cool Setpoint (degrees)
Default: 0x16003e52 10:00PM 62F / 82F
0x1600101b 10:00PM 16C / 27CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0.
This parameter has the configuration ID config_255_4 and is of type INTEGER.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The device does not support associations.
| Command Class | Comment |
|---|---|
| COMMAND_CLASS_NO_OPERATION_V1 | |
| COMMAND_CLASS_BASIC_V1 | |
| COMMAND_CLASS_SCENE_ACTIVATION_V1 | |
| COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1 | |
| COMMAND_CLASS_SENSOR_MULTILEVEL_V5 | |
| COMMAND_CLASS_THERMOSTAT_MODE_V1 | |
| COMMAND_CLASS_THERMOSTAT_OPERATING_STATE_V2 | |
| COMMAND_CLASS_THERMOSTAT_SETPOINT_V2 | |
| COMMAND_CLASS_THERMOSTAT_FAN_MODE_V2 | |
| COMMAND_CLASS_THERMOSTAT_FAN_STATE_V1 | |
| COMMAND_CLASS_CONFIGURATION_V1 | |
| COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
| COMMAND_CLASS_POWERLEVEL_V1 | |
| COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
| COMMAND_CLASS_CLOCK_V1 | |
| COMMAND_CLASS_ASSOCIATION_V1 | |
| COMMAND_CLASS_VERSION_V1 | |
| COMMAND_CLASS_MULTI_CMD_V1 |