| layout | documentation |
|---|---|
| title | ZM1601 - ZWave |
{% include base.html %}
This describes the Z-Wave device ZM1601, manufactured by Vision Security with the thing type UID of vision_zm1601_00_000.
The device is in the category of Siren, defining Siren used by Alarm systems.
The ZM1601 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
This product will sound a loud siren and flash a strobe light when an alarm message or alert is received on any Z-Wave enabled network.
Open the bracket and press the program switch of ZM 1601 for 1 second at least & release to be included. After setting, the LED Setting Lighting should go off, if not, please try again.
Press the program switch of ZM 1601 for 1 second at least & release to be excluded.
Note: LED setting light will flash (orange color) continuously in Exclusion condition.
The following table summarises the channels available for the ZM1601 -:
| Channel Name | Channel ID | Channel Type | Category | Item Type |
|---|---|---|---|---|
| Switch | switch_binary | switch_binary | Switch | Switch |
| Alarm (general) | alarm_general | alarm_general | Alarm | Switch |
| Alarm (burglar) | alarm_burglar | alarm_burglar | Door | Switch |
| Battery Level | battery-level | system.battery_level | Battery | Number |
Switch the power on and off.
The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.
Indicates if an alarm is triggered.
The alarm_general channel is of type alarm_general and supports the Switch item and is in the Alarm category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch item type -:
| Value | Label |
|---|---|
| OFF | OK |
| ON | Alarm |
Indicates if the burglar alarm is triggered.
The alarm_burglar channel is of type alarm_burglar and supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch item type -:
| Value | Label |
|---|---|
| OFF | OK |
| ON | Alarm |
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The system.battery-level channel is of type system.battery-level and supports the Number item and is in the Battery category.
This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.
The following table provides a summary of the 2 configuration parameters available in the ZM1601. Detailed information on each parameter can be found in the sections below.
| Param | Name | Description |
|---|---|---|
| 1 | Siren Strobe Mode | Defines the reaction of the siren |
| 2 | Alarm auto stop | Defines the auto time out of the alarm indication |
Defines the reaction of the siren
The following option values may be configured -:
| Value | Description |
|---|---|
| 0 | All Enabled |
| 1 | Siren Only |
| 2 | Strobe Only |
The manufacturer defined default value is 0 (All Enabled).
This parameter has the configuration ID config_1_1 and is of type INTEGER.
Defines the auto time out of the alarm indication
The following option values may be configured -:
| Value | Description |
|---|---|
| 0 | 30 seconds |
| 1 | 60 seconds |
| 2 | 120 seconds |
| 3 | Continuous |
The manufacturer defined default value is 0 (30 seconds).
This parameter has the configuration ID config_2_1 and is of type INTEGER.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZM1601 supports 1 association group.
Association group 1 supports 5 nodes.
| Command Class | Comment |
|---|---|
| COMMAND_CLASS_NO_OPERATION_V1 | |
| COMMAND_CLASS_BASIC_V1 | |
| COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
| COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
| COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
| COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
| COMMAND_CLASS_CONFIGURATION_V1 | |
| COMMAND_CLASS_ALARM_V4 | |
| COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
| COMMAND_CLASS_POWERLEVEL_V1 | |
| COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
| COMMAND_CLASS_BATTERY_V1 | |
| COMMAND_CLASS_ASSOCIATION_V2 | |
| COMMAND_CLASS_VERSION_V2 |