This describes the Z-Wave device ZEN22, manufactured by Willis Electric Co., Ltd. with the thing type UID of willis_zen22_00_000.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The ZEN22 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
PRODUCT FEATURES:
- Manual or remote on/off control and dimming from your mobile device or computer (when included to a Z-Wave gateway controller)
- Z-Wave Plus with improved 500 chip for faster and safer wireless communication
- Works with most high-quality DIMMABLE LED, CFL, and incandescent bulbs
- Based on universal command classes - supported by most Z-Wave controllers
- May be associated and grouped with other Z-Wave devices for advanced home automation
- LED indicator to help locate the switch in dark space
- Simple elegant design with screwless snap-on wall plate included
- Built-in Z-Wave signal repeater for a stronger and more reliable network
Tap the switch on and off quickly 3 times to finalize the inclusion process
Tap the switch on and off quickly 3 times to complete the exclusion process
The following table summarises the channels available for the ZEN22 -:
| Channel Name | Channel ID | Channel Type | Category | Item Type |
|---|---|---|---|---|
| Switch | switch_binary | switch_binary | Switch | Switch |
| Dimmer | switch_dimmer | switch_dimmer | DimmableLight | Dimmer |
Switch the power on and off.
The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer channel is of type switch_dimmer and supports the Dimmer item and is in the DimmableLight category.
The following table provides a summary of the 3 configuration parameters available in the ZEN22. Detailed information on each parameter can be found in the sections below.
| Param | Name | Description |
|---|---|---|
| 1 | Paddle Functions | Paddle Functions |
| 2 | LED Indicator Function | LED Indicator Function |
| 3 | Enable / Disable LED | Enable / Disable LED |
| Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Paddle Functions
The following option values may be configured -:
| Value | Description |
|---|---|
| 0 | Upper paddle turns the light on, |
| 1 | Upper paddle turns the light off |
The manufacturer defined default value is 0 ( Upper paddle turns the light on,).
This parameter has the configuration ID config_1_1 and is of type INTEGER.
LED Indicator Function
The following option values may be configured -:
| Value | Description |
|---|---|
| 0 | LED indicator is on when switch is off |
| 1 | LED indicator is on when switch is on |
The manufacturer defined default value is 0 (LED indicator is on when switch is off).
This parameter has the configuration ID config_2_1 and is of type INTEGER.
Enable / Disable LED
The following option values may be configured -:
| Value | Description |
|---|---|
| 0 | LED enabled |
| 1 | LED disabled |
The manufacturer defined default value is 0 (LED enabled).
This parameter has the configuration ID config_3_1 and is of type INTEGER.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
| Value | Description |
|---|---|
| 0 | Exclude from All On and All Off groups |
| 1 | Include in All On group |
| 2 | Include in All Off group |
| 255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode and is of type INTEGER.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZEN22 supports 1 association group.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.
Association group 1 supports 5 nodes.
| Command Class | Comment |
|---|---|
| COMMAND_CLASS_NO_OPERATION_V1 | |
| COMMAND_CLASS_BASIC_V1 | |
| COMMAND_CLASS_SWITCH_BINARY_V1 | |
| COMMAND_CLASS_SWITCH_MULTILEVEL_V1 | Linked to BASIC |
| COMMAND_CLASS_SWITCH_ALL_V1 | |
| COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
| COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
| COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
| COMMAND_CLASS_CONFIGURATION_V1 | |
| COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
| COMMAND_CLASS_POWERLEVEL_V1 | |
| COMMAND_CLASS_ASSOCIATION_V2 | |
| COMMAND_CLASS_VERSION_V2 |