This describes the Z-Wave device PAN04, manufactured by Zipato with the thing type UID of zipato_pan04_00_000.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The PAN04 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
This product can be operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. Micro module Switch Double is a transceiver which is a Z-Wave Plus enabled device and is fully compatible with any Z-Wave enabled network. Mini size design allow the module to be easily hidden into the wall box which is good for the house decoration.
There are many kinds of application for using the module to switch AC power ON and OFF, one of which is the light control. The new smart relay calibration technology can reduce the inrush current caused by the load and let the module work perfectly with many kinds of light like incandescent, fluorescent and LED light.
This Micro module is able to detect Instant power wattage and overload wattage (current 7.5A) of connected light or appliances. When detecting overload state, the switch will be disabled and its ON/OFF button will be locked during which LED will flash repeatedly. Unplugging and reconnecting the Module will reset its overload condition to normal status.
Have Z-Wave Controller entered inclusion mode by following the instructions provided by the controller manufacturer.
Pressing INCLUDE_BUTTON three times within 2 seconds will enter inclusion mode.
Have Z-Wave Controller entered exclusion mode by following the instructions provided by the controller manufacturer.
Pressing INCLUDE_BUTTON three times within 2 seconds will enter exclusion mode.Node ID has been excluded.
The following table summarises the channels available for the PAN04 -:
| Channel Name | Channel ID | Channel Type | Category | Item Type |
|---|---|---|---|---|
| Switch | switch_binary | switch_binary | Switch | Switch |
| Scene Number | scene_number | scene_number | Number | |
| Electric meter (amps) | meter_current | meter_current | Energy | Number |
| Electric meter (power factor) | meter_powerfactor | meter_powerfactor | Energy | Number |
| Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number |
| Electric meter (volts) | meter_voltage | meter_voltage | Energy | Number |
| Electric meter (watts) | meter_watts | meter_watts | Energy | Number |
| Alarm | alarm_general | alarm_general | Alarm | Switch |
| Switch 1 | switch_binary1 | switch_binary | Switch | Switch |
| Electric meter (amps) 1 | meter_current1 | meter_current | Energy | Number |
| Electric meter (power factor) 1 | meter_powerfactor1 | meter_powerfactor | Energy | Number |
| Electric meter (kWh) 1 | meter_kwh1 | meter_kwh | Energy | Number |
| Electric meter (volts) 1 | meter_voltage1 | meter_voltage | Energy | Number |
| Electric meter (watts) 1 | meter_watts1 | meter_watts | Energy | Number |
| Switch 2 | switch_binary2 | switch_binary | Switch | Switch |
| Electric meter (amps) 2 | meter_current2 | meter_current | Energy | Number |
| Electric meter (power factor) 2 | meter_powerfactor2 | meter_powerfactor | Energy | Number |
| Electric meter (kWh) 2 | meter_kwh2 | meter_kwh | Energy | Number |
| Electric meter (volts) 2 | meter_voltage2 | meter_voltage | Energy | Number |
| Electric meter (watts) 2 | meter_watts2 | meter_watts | Energy | Number |
| Switch 3 | switch_binary3 | switch_binary | Switch | Switch |
| Electric meter (amps) 3 | meter_current3 | meter_current | Energy | Number |
| Electric meter (power factor) 3 | meter_powerfactor3 | meter_powerfactor | Energy | Number |
| Electric meter (kWh) 3 | meter_kwh3 | meter_kwh | Energy | Number |
| Electric meter (volts) 3 | meter_voltage3 | meter_voltage | Energy | Number |
| Electric meter (watts) 3 | meter_watts3 | meter_watts | Energy | Number |
Switch the power on and off.
The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.
Triggers when a scene button is pressed.
The scene_number channel is of type scene_number and supports the Number item.
Indicates the instantaneous current consumption.
The meter_current channel is of type meter_current and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power factor.
The meter_powerfactor channel is of type meter_powerfactor and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous voltage.
The meter_voltage channel is of type meter_voltage and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power consumption.
The meter_watts channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.
Indicates if an alarm is triggered.
The alarm_general channel is of type alarm_general and supports the Switch item and is in the Alarm category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch item type -:
| Value | Label |
|---|---|
| OFF | OK |
| ON | Alarm |
Switch the power on and off.
The switch_binary1 channel is of type switch_binary and supports the Switch item and is in the Switch category.
Indicates the instantaneous current consumption.
The meter_current1 channel is of type meter_current and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power factor.
The meter_powerfactor1 channel is of type meter_powerfactor and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh1 channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous voltage.
The meter_voltage1 channel is of type meter_voltage and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power consumption.
The meter_watts1 channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.
Switch the power on and off.
The switch_binary2 channel is of type switch_binary and supports the Switch item and is in the Switch category.
Indicates the instantaneous current consumption.
The meter_current2 channel is of type meter_current and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power factor.
The meter_powerfactor2 channel is of type meter_powerfactor and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh2 channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous voltage.
The meter_voltage2 channel is of type meter_voltage and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power consumption.
The meter_watts2 channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.
Switch the power on and off.
The switch_binary3 channel is of type switch_binary and supports the Switch item and is in the Switch category.
Indicates the instantaneous current consumption.
The meter_current3 channel is of type meter_current and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power factor.
The meter_powerfactor3 channel is of type meter_powerfactor and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh3 channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous voltage.
The meter_voltage3 channel is of type meter_voltage and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power consumption.
The meter_watts3 channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.
The device has no configuration parameters defined.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The device does not support associations.
| Command Class | Comment |
|---|---|
| COMMAND_CLASS_NO_OPERATION_V1 | |
| COMMAND_CLASS_BASIC_V1 | |
| COMMAND_CLASS_SWITCH_BINARY_V1 | |
| COMMAND_CLASS_SWITCH_ALL_V1 | |
| COMMAND_CLASS_SCENE_ACTIVATION_V1 | |
| COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1 | |
| COMMAND_CLASS_METER_V3 | |
| COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
| COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
| COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
| COMMAND_CLASS_MULTI_CHANNEL_V2 | |
| COMMAND_CLASS_CONFIGURATION_V1 | |
| COMMAND_CLASS_ALARM_V1 | |
| COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
| COMMAND_CLASS_POWERLEVEL_V1 | |
| COMMAND_CLASS_PROTECTION_V2 | |
| COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
| COMMAND_CLASS_ASSOCIATION_V2 | |
| COMMAND_CLASS_VERSION_V2 |
| Command Class | Comment |
|---|---|
| COMMAND_CLASS_BASIC_V1 | |
| COMMAND_CLASS_SWITCH_BINARY_V1 | |
| COMMAND_CLASS_METER_V3 |
| Command Class | Comment |
|---|---|
| COMMAND_CLASS_BASIC_V1 | |
| COMMAND_CLASS_SWITCH_BINARY_V1 | |
| COMMAND_CLASS_METER_V3 |
| Command Class | Comment |
|---|---|
| COMMAND_CLASS_BASIC_V1 | |
| COMMAND_CLASS_SWITCH_BINARY_V1 | |
| COMMAND_CLASS_METER_V3 |