This describes the Z-Wave device PAN08, manufactured by Zipato with the thing type UID of zipato_pan08_00_000.
The device is in the category of Blinds, defining Roller shutters, window blinds, etc..
The PAN08 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Roller shutter micromodule
Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer.
Pressing Include button three times within 2 seconds will enter inclusion mode.
Put the Z-Wave Controller in exclusion mode.
Pressing Include button three times within 2 seconds will enter exclusion mode.
Node ID has been excluded.
The following table summarises the channels available for the PAN08 -:
| Channel Name | Channel ID | Channel Type | Category | Item Type |
|---|---|---|---|---|
| Blinds Control | blinds_control | blinds_control | Blinds | Rollershutter |
| Scene Number | scene_number | scene_number | Number | |
| Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number |
| Electric meter (amps) | meter_current | meter_current | Energy | Number |
| Electric meter (volts) | meter_voltage | meter_voltage | Energy | Number |
| Electric meter (watts) | meter_watts | meter_watts | Energy | Number |
| Electric meter (power factor) | meter_powerfactor | meter_powerfactor | Energy | Number |
| Alarm | alarm_general | alarm_general | Alarm | Switch |
Provides start / stop control of blinds.
The blinds_control channel is of type blinds_control and supports the Rollershutter item and is in the Blinds category.
Triggers when a scene button is pressed.
The scene_number channel is of type scene_number and supports the Number item.
Indicates the energy consumption (kWh).
The meter_kwh channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous current consumption.
The meter_current channel is of type meter_current and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous voltage.
The meter_voltage channel is of type meter_voltage and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power consumption.
The meter_watts channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power factor.
The meter_powerfactor channel is of type meter_powerfactor and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.
Indicates if an alarm is triggered.
The alarm_general channel is of type alarm_general and supports the Switch item and is in the Alarm category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch item type -:
| Value | Label |
|---|---|
| OFF | OK |
| ON | Alarm |
The following table provides a summary of the 4 configuration parameters available in the PAN08. Detailed information on each parameter can be found in the sections below.
| Param | Name | Description |
|---|---|---|
| 1 | Watt meter report interval (5s) | Interval (x5 seconds) to send out watt meter report |
| 2 | KWH Meter Report Interval (10min) | Interval (x10 minutes) to send out KWH Meter Report |
| 3 | Threshold for Load Caution (10mA) | Threshold (x0.01A) of current for Load Caution |
| 4 | Threshold of KWh for Load Caution |
Interval (x5 seconds) to send out watt meter report
Values in the range 1 to 32767 may be set.
The manufacturer defined default value is 720.
This parameter has the configuration ID config_1_2 and is of type INTEGER.
Interval (x10 minutes) to send out KWH Meter Report
Values in the range 1 to 32767 may be set.
The manufacturer defined default value is 6.
This parameter has the configuration ID config_2_2 and is of type INTEGER.
Threshold (x0.01A) of current for Load Caution
Values in the range 1 to 1100 may be set.
The manufacturer defined default value is 1100.
This parameter has the configuration ID config_3_2 and is of type INTEGER.
Values in the range 1 to 10000 may be set.
The manufacturer defined default value is 10000.
This parameter has the configuration ID config_4_2 and is of type INTEGER.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The PAN08 supports 1 association group.
Association group 1 supports 1 node.
| Command Class | Comment |
|---|---|
| COMMAND_CLASS_NO_OPERATION_V1 | |
| COMMAND_CLASS_BASIC_V1 | |
| COMMAND_CLASS_SWITCH_BINARY_V1 | |
| COMMAND_CLASS_SWITCH_MULTILEVEL_V3 | |
| COMMAND_CLASS_SCENE_ACTIVATION_V1 | |
| COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1 | |
| COMMAND_CLASS_METER_V3 | |
| COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
| COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
| COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
| COMMAND_CLASS_CONFIGURATION_V1 | |
| COMMAND_CLASS_ALARM_V1 | |
| COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
| COMMAND_CLASS_POWERLEVEL_V1 | |
| COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
| COMMAND_CLASS_ASSOCIATION_V1 | |
| COMMAND_CLASS_VERSION_V1 |