Skip to content

Add extended KNX smoke alarm support (Gira): extra fault channels, temperature, siren control, and fault acknowledge#85

Open
wlcrs wants to merge 2 commits into
athombv:masterfrom
wlcrs:extended_smoke_alarm_support
Open

Add extended KNX smoke alarm support (Gira): extra fault channels, temperature, siren control, and fault acknowledge#85
wlcrs wants to merge 2 commits into
athombv:masterfrom
wlcrs:extended_smoke_alarm_support

Conversation

@wlcrs
Copy link
Copy Markdown

@wlcrs wlcrs commented May 15, 2026

Hi Homey team,

This PR extends the KNX smoke sensor device to support the full set of relevant group addresses exposed by Gira smoke alarm objects, beyond the previously supported smoke-only channel. All new functions are implemented as optional.

This PDF documents the newly implemented KNX objects:
gira_knx_documentation.pdf

What was added:

  • Support for additional smoke-alarm related addresses:
    • General alarm
    • Heat alarm
    • Signal: a writable object to start/stop the siren (uiQuickAction disabled because of that)
    • Temperature
    • Battery fault
    • 230V fault
    • Smoke sensor fault
    • Temperature sensor fault
    • Fault acknowledge
  • Dynamic capability handling based on configured group addresses (only show capabilities that are configured).
  • Pairing and settings updates to configure all supported smoke sensor addresses in a clear order.
  • Localized labels for the new smoke sensor fields.